Honda Fit/Jazz - Recirculation Control Motor Test
Recirculation Control Motor Test
NOTE: Check for HVAC DTCs.
1. | Disconnect the 7P connector from the recirculation control motor.
Incorrectly applying power and ground to the recirculation control motor will damage it. Follow the instructions carefully.
|
2. | Connect battery power to the No. 1 terminal of the recirculation control motor, and ground the No. 5 and No. 7 terminals; the recirculation control motor should run smoothly. To avoid damaging the recirculation control motor, do not reverse power and ground. Disconnect the No. 5 or No. 7 terminals from ground; the recirculation control motor should stop at Fresh (when the No. 5 terminal is disconnected) or Recirculate (when the No. 7 terminal is disconnected). Don't cycle the recirculation control motor for a long time.
|
replace the recirculation control motor.
If the linkage or doors stick or bind, repair them as needed.
Honda Fit/Jazz 02-05 Workshop Manual